HIA Software - Change Log - v2.2
Bug correction
- Calculation of average image offset from data with NaN values
- NaN values are not included in the calculation of the average
- 4D data mask images saved as stacks - masks are saved
correctly as hyperstacks
- Spectra projection results not displaying - results are now
displayed
- Spectra projection function using input spectra with different
spectral points as the data returned an error - error is
corrected and any spectra with spectral range wider than data
can be used
- Import of fit parameters for uneven background correction of
4D data returned an error - function is now corrected
- SVD masking function of data containing previously excluded
regions returned an error - function is now corrected
- If the user activated the freehand or the polygonal selector
at the exclude regions panel and exit or press 'ok' without
selecting the region the function returned an error - function
is now correct
- Error in the cosmic ray removal function for 4D data -
function is now corrected
Modifications
- Mask images are now saved as 1bit tiff
- Pop-up panel to confirm data deletion
New implementations
- Import ASCII panel has now Save/Load/Reset functions for fast
input
- New function to remove spectral background using robust
fitting
- New function to correct slowly varying phase offset in PCKK
analysis using robust fitting
Created by Francesco Masia,
08/07/2015, Updated by FM 21/09/2015